CLKRN - 2-2SCL, NICKEL-CADMIUM SEALED CELL BATTERY

  • MSDS: CLKRN
  • Manufacturer: SAFT AMERICA INC
  • Product Name: 2-2SCL, NICKEL-CADMIUM SEALED CELL BATTERY
  • National Stock Number: 6140-00-941-6940
Product Identification

Product ID:2-2SCL, NICKEL-CADMIUM SEALED CELL BATTERY
MSDS Date:02/28/1991
FSC:6140
NIIN:00-941-6940
Status Code:A
MSDS Number: CLKRN

Responsible Party
SAFT AMERICA INC.
711 INDUSTRIAL BLVD
VALDOSTA, GA 31602
US

Emergency Phone: 912-247-2331

Info Phone: 912-247-2331

Preparer: WILLIAM A.

Cage: 09052

Contractor
TNR TECHNICAL INC
SANFORD, FL 32771 US

Telephone: 407-321-3011

Cage: 1HJ92

Ingredients

CADMIUM (PRESENT AS CADMIUM,

OSHA PEL 0.2 TWA DUST

ACGIH TLV: 0.05 TWA DUST


CADMIUM HYDROXIDE, CADMIUM OXIDE)

Fraction By Weight: SEE #1%

OSHA PEL 0.6 C DUST

ACGIH TLV: 0.05 C FUME


NICKEL (PRESENT AS NICKEL,

OSHA PEL 1 AS NICKEL

ACGIH TLV: 1 AS NICKEL


NICKEL HYDROXIDE, NICKEL OXIDE)

Fraction By Weight: SEE #3%

Hazards

Reports of Carcinogenicity:NTP:YES IARC:YES OSHA:YES
Health Hazards Acute and Chronic:PER CFR 1910.1200 "(C)": THESE
BATTERIES ARE MANUFACTURED "ARTICLES", WHICH DO NOT RESULT IN
EXPOSURE TO A HAZARDOUS CHEMICAL UNDER NORMAL CONDITIONS OR USE.
FOR THIS REASON, AN MSDS IS NOT REQUIRED. THE MSDS IS THEREFORE
SUPPLIED FOR INFORMATION PURPOSES ONLY. HEALTH HAZARDS: NOT
APPLICABLE FOR FINISHED PRODUCT USED UNDER NORMAL CONDITIONS.
Explanation of Carcinogenicity:NICKEL AND CADMIUM AND THEIR COMPOUNDS
ARE LISTED AS CARCINOGENS OR POTENTIAL CARCINOGENS BY NTP, IARC,
AND OSHA.
Effects of Overexposure:ACUTE AND CHRONIC): NOT APPLICABLE FOR FINISHED
PRODUCT USED UNDER NORMAL CONDITIONS. SYMPTOMS OF EXPOSURE:
IRRITATION OF NOSE AND THROAT, SWEATING, CHILLS, SHORTNESS OF
BREATH, WEAKNESS, LOCAL DERMAT ITIS, NAUSEA, COUGHING, CHEST PAINS.
Medical Cond Aggravated by Exposure:RESPIRATORY SYSTEM DISORDERS,
PROSTATE DISORDERS, LIVER AND KIDNEY DISORDERS.

First Aid

First Aid:INHALATION: REMOVE FROM EXPOSURE, SEE PHYSICIAN, INGESTION:
INDUCE VOMITING IF CONSCIOUS, SEE A PHYSICIAN, SKIN OR EYES: FLUSH
WITH WATER FOR 15 MINUTES. SEE PHYSICIAN IF SYMPTOMS DEVELOP.

Fire Fighting

Flash Point:NONE
Extinguishing Media:DRY CHEMICAL, CO2, WATER.
Fire Fighting Procedures:USE NIOSH/MSHA APPROVED SELF-CONTAINED
BREATHING APPARATUS WITH FULL PROTECTIVE CLOTHING IF INVOLVED IN A
FIRE.

Accidental Release

Spill Release Procedures:CONTAIN THE SPILL. COLLECT THE SPILLED
MATERIAL AND PLACE IN A PLASTIC-LINED CONTAINER. HEPA VACUUMING IS
PREFERRED. WASH THE AREA WITH WATER.

Handling

Handling and Storage Precautions:WEAR NIOSH/MSHA APPROVED DUST MASKS OR
RESPIRATORS; IMPERVIOUS GLOVES; AND SAFETY GLASSES OR GOGGLES.
Other Precautions:KEEP CONTAINER CLOSED, AVOID CONTACT WITH CLOTHING,
AVOID GENERATING DUST.

Exposure Controls

Respiratory Protection:USE NIOSH/MSHA APPROVED FOR DUSTS.
Ventilation:USE LOCAL EXHAUST AND MECHANICAL (GENERAL) TO MAINTAIN
OSHA PEL.
Protective Gloves:IMPERVIOUS
Eye Protection:SAFETY GLASSES/GOGGLES
Other Protective Equipment:DO NOT WEAR CONTAMINATED CLOTHING HOME.
SHOWER AND CHANGE OR WEAR COVERALLS.
Work Hygienic Practices:KEEP FOOD AND TOBACCO AWAY FROM WORK AREA.
Supplemental Safety and Health
NONE SPECIFIED BY MANUFACTURER.

Chemical Properties

HCC:Z5
Melt/Freeze Pt:M.P/F.P Text:NOT AVAILABLE
Vapor Density:N/R (AIR=1
Spec Gravity:1.6 (H20=1)

Stability

Stability Indicator/Materials to Avoid:YES
Stability Condition to Avoid:GENERAL STORAGE PROCEDURES FOR HAZARDOUS
MATERIALS ARE ACCEPTABLE. AVOID SHORTING, USE ONLY APPROVED
CHARGING METHODS.
Hazardous Decomposition Products:METAL OXIDE FUMES MAY BE EVOLVED AT
TEMPERATURES ABOVE MELTING POINT.
Conditions to Avoid Polymerization:WILL NOT OCCUR. DO NOT PUNCTURE
BATTERY CASE.

Disposal

Waste Disposal Methods:DISPOSE IN ACCORDANCE WITH FEDERAL, STATE, AND
LOCAL LAWS. IF DISCARDED, TREAT AS HAZARDOUS WASTE.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.